Edition number: 31 Year: 2021.

Title: GRAPHICAL METHOD FOR DETERMINATION OF MQ-SERIES GAS SENSOR CIRCUIT PARAMETERS FOR A STAND-ALONE GAS ALARM SYSTEM

Abstract:
Background: MQ-series gas sensors belong to the metal oxide semiconductor (MOS) family of sensors that can sense the presence of many gases. These sensors find their application in gas alarm systems as key components. While necessary sensor circuit output voltage value for alarm point in a stand-alone gas alarm system is desirable, but what exact combination of the sensor circuit parameters is required? Hitherto, the determination of these circuit parameters has not been given much attention in the research community. Aim: the purpose of this work is to explore a structured graphical approach of determination of MQ series gas sensor circuit parameters for a stand-alone gas alarm system that yields desired sensor circuit output voltage value for the alarm point; the main objective of the study was to develop mathematical model equations that relate the: (i) sensor resistance (RS) with the gas concentration (x) and the sensor resistance at standard calibration concentration of the sensor base gas in the clean air (Ro) and (ii) sensor circuit output voltage (VRL), load resistance (RL) and sensor resistance (RS). It is expected from the model equations developed that graphical correlations of the sensor circuits parameters will be generated. Using these graphs for a particular case of an MQ-4 gas sensor under the influence of LPG, the parameters that yield desired sensor circuit output voltage of 2V for 1000 ppm of LPG alarm point will be determined. Methods: Model equations were developed for the sensor dynamics, and based on these model equations, graphs for the determination of required sensor parameters were plotted for a case of MQ-4 gas sensor response to LPG. Results and Discussion: The results yielded optimal values for R_O,R_S and R_L of 20 kΩ, 30 kΩ and 20 kΩ respectively, for alarm settings of 1000 ppm and a desired sensor circuit output voltage of 2 V. Based on determined parameters, the calibration equation for determination of best concentration value for a given value of emulated LPG concentration was developed. Using the method proposed in this study makes the process of determining the MQ-series gas sensor circuit parameters less cumbersome as their value can easily be obtained from the resulting graphs. Conclusions: a structured graphical approach for determination of MQ-series gas sensor circuit parameters for alarm points in a stand-alone gas alarm system showed that using MQ-4 gas sensor and LPG as the target gas, and for a sensor circuit output voltage of 2 V for alarm point at 1000 ppm of LPG, the corresponding value of R_O, R_S and R_L obtained were 20 kΩ, 30 kΩ, and 20 kΩ respectively. Hence, a structured graphical approach is suitable for determining MQ series gas sensor circuit parameters for a stand-alone gas alarm system under the influence of its associated gases.

Link: Open

DOI: 10.48141/SJS.v29.n31.2021.01_AJIBOYE_pgs_01_09.pdf